- Home
- Categories
- Generators
- Panda 30 ICx PMS
Description
Panda Marine Standard (PMS) diesel generators with dual circuit cooling (seawater cooling with heat exchanger) and "wet exhaust". 50 Hz 3000 rpm in three versions:
- HP1 (single phase 230V)
- HP 3 (three phase 3 x 400V)
- DVS (combined windings - 230V and 400 V).
General Technical Data
Model: Panda 30 ICx PMS
Generator Type: Generators with regulated speed (3000 rpm 50 Hz)
- Brushless
- No signal noise
- No rotating coils or diodes
- Precise control
- High protection rating
- Perfect sine wave
- Short-circuit stability
- Water-cooled
- Overload protection
Generator Family: 30 ICx
- external 12V fuel pump
Generator Version: PMS
- Suitable for internal installation
- Low ambient temperatures
- External control panel with cable
- Dual circuit cooling
Additional Features: Alternator for charging the starter battery
Area of Application: Marine Generator (M)
Frequency [Hz]: 50
Generator manufacturer: Fischer Panda GmbH
Isolation class of windings: H
Nominal Speed [rpm]: 3000 rpm
Voltage Regulation: xControl
Power rating factor Cos Pi: 0.85
Excitation by: MKP Capacitors
Electrical Alternator
Single Phase Winding - Standard version
Alternator Type: HP1
Nominal Voltage in Volt: 230
Nominal Performance in kW(1): 27.00
Nominal Performance in kVA(1): 31.8
Continuous Performance in kW(1): 24.3
Continuous Performance in kVA(1): 28.6
Number of Phases: 1
Frequency [Hz]: 50
1) up to Panda 15000 / 12-4 cosPhi 0,85 for short take-off power to inductive loads, otherwise cosPhi1
1) from Panda 18 /17-4 on cosPhi 0,85 optional startup performance with compensation or starting current boost, otherwise cosPhi1
All performance data applies to generator operation at 100m above sea level at 20°C. Performance reductions can occur when operating at greater heights.
Engine Data
Engine Manufacturer: Kubota (KU)
Engine Type: V 1505 T IC
No. Cylinders: 4
Displacement [cm3]: 1498
Starter System: 12V (24V Optional)